Page 3 of 3
Insulation Type
Temp Class
200
o
C
200
o
C
220
o
C
Sizes
0.190mm to 5.000mm
0.190mm to 5.000mm
0.190mm to 5.000mm
Reference
IS 13730 (Part-13) : 1993
IS 13730 (Part-13) : 1993
IS 13730 (Part-7) : 1993
Dimensions
As per IEC 317 - 0 -1
As per IEC 317 - 0 -1
As per IEC 317 - 0 -1
Electrical Resistance
As per IEC 317 - 0 -1
As per IEC 317 - 0 -1
As per IEC 317 - 0 -1
Elongation
As per IEC 317 - 0 -1
As per IEC 317 - 0 -1
As per IEC 317 - 0 -1
Springiness
As per IEC 317 - 0 -1
As per IEC 317 - 0 -1
As per IEC 317 - 0 -1
Flexibility & Adherence
As per IEC 317 - 0 -1
K 75 mm
As per IEC 317 - 0 -1
K 110 mm
As per IEC 317 - 0 -1
K 90 mm
Heat Shock
Min. Temp. 220
o
C
As per IEC 317 - 0 - 1
Min.Temp220
o
C
As per
IEC 317 - 0 - 1
Min. Temp. 240
o
C
As per
IEC 317 - 0 - 1
Cut Through
No Failure will occur within 2 Min. at 350
o
C
No Failure will occur within 2 Min. at 350
o
C
No Failure will occur within 2 Min. at 400
o
C
Resistance to Abrasion
O from 0.250 mm to 1.600 mm
Resistance to Solvents
As per IEC 317 - 0 - 1
As per IEC 317 - 0 - 1
As per IEC 317 - 0 - 1
Breakdown Voltage Test
As per IEC 317 - 0 -1
Elevated Temp. 200
o
C
As per IEC 317 - 0 -1
Elevated Temp. 200
o
C
As per IEC 317 - 0 -1
Elevated Temp. 220
o
C
Continuity of Insulation
As per IEC 317 - 0 - 1
As per IEC 317 - 0 - 1
As per IEC 317 - 0 - 1
Temperature Index Test
(If specified)
Elevated Temp. 200
o
C
Elevated Temp. 200
o
C
Elevated Temp. 220
o
C
Resistance to refrigerants
Test Appropriate but no requirement Specified
refrigerent - extraction with trichloroehylene / methanol / monochlorodifluoromethane or blistering with monochloro difluoromethane
Test Appropriate but no requirement Specified
Solderability
Test Inappropriate
Test Inappropriate
Test Inappropriate
Heat and Solvent Bonding
Test Inappropriate
Test Inappropriate
Test Inappropriate
Dielectric Dissipation Factor
Test Inappropriate
Test Inappropriate
Dissipation Factor tan
d < 60 x 10
-4
at a frequency of 1000 Hz.
Resistance to Transformer Oil
Test Appropriate but no requirement Specified
Test Appropriate but no requirement Specified
Test Appropriate but no requirement Specified
Loss of Mass
Test Inappropriate
Test Inappropriate
Test Inappropriate
High Temperature Failure
Test Appropriate but no requirement Specified
Test Appropriate but no requirement Specified
Test Appropriate but no requirement Specified
Packaging
As per IEC 317 - 0 - 1
As per IEC 317 - 0 - 1
As per IEC 317 - 0 - 1
* This insulation is also available for aluminium wire & strips
Copyright Vidarbha Winding Wires Ltd.@2003.